Cytiva Colonne di cromatografia XK (a vuoto)

Codice prodotto. p-4948800 Sfoglia Tutto Cytiva Prodotti
300 mm, 50 mm, Pezzo
Click to view available options
Altezza (sistema metrico):
200 mm
300 mm
400 mm
600 mm
700 mm
1000 mm
Diametro (sistema metrico) interno:
16 mm
26 mm
50 mm
Dimensione della confezione:
Pezzo
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Ensure trouble-free operation for low to medium pressure. Cytiva XK Chromatography Columns (Empty) connect directly to ÄKTA design instruments or other liquid chromatography systems. The user-friendly ensures reproducible, accurate packing.

XK columns are constructed of robust borosilicate glass, which exhibits excellent chemical resistance and is compatible with aqueous solutions and most organic solvents used in liquid chromatography of macromolecules. The clear tubes allow for visual inspection of the media bed and are available in a broad range of column dimensions for use with many different purification needs.

Column packing can be performed using either a packing reservoir or an extra column tube attached with a packing connector. The QuickLock mechanism of the adapter shaft facilitates rapid and easy movement of the adapter, simplifying adjustments of the bed height, disassembly, and cleaning. The design of the adapter plunger gives a uniform flow, which maintains the integrity of the packed bed during operations.

  • Plunger design to ensure a homogeneous buffer distribution and reproducible packing
  • Adapter QuickLock mechanism that facilitates column handling and cleaning
  • Fittings for direct connection to chromatographiy systems
  • Cooling jacket for sensitive purifications
  • Extensive range of spare parts available, facilitating maintenance
TRUSTED_SUSTAINABILITY

Specifica

Product Type XK Chromatography Columns (Empty)
Volume letto Bed height (one adapter): 140 to 280mm
Bed height (two adapters): 0 to 280mm
Diametro (sistema metrico) interno 50 mm
Altezza (sistema metrico) 300 mm
Portata Inlet/Outlet (i.d.): 1.55mm
Materiale Borosilicate glass
Pressione max 3 bar
Dimensione particelle 10μm pore size
Support Type Polypropylene (reinforced glass fiber)/Polyamide Net
Tipo di colonna Empty Chromatography Column
Da utilizzare con (applicazione) Liquid chromatography at low to medium pressure
Vedi altri risultati Mostra meno risultati

Not resistant to Acetone, Ketones, Chlorinated Hydrocarbons, Aliphatic Esters and Phenol.

Should be avoided: >10% NaOH, >10% HCl, >5% acetic acid, and strong mineral acids.

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto
Cytiva Colonne di cromatografia XK (a vuoto) >

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato