missing translation for 'onlineSavingsMsg'
Learn More

Lead(II) chloride, ultra dry, 99.999% (metals basis), Thermo Scientific Chemicals

Used in the synthesis of lead titanate and barium lead titanate ceramics; employed in the production of infrared transmitting glass and ornamental glass (aurene glass); useful as an electrode in geophysical applications and in solar cells.

69.35€ - 775.86€

Identificatori chimici

CAS 7758-95-4
Formula molecolare Cl2Pb
Molecular Weight (g/mol) 278.10
Numero MDL MFCD00011157
InChI Key HWSZZLVAJGOAAY-UHFFFAOYSA-L
Sinonimo lead dichloride, lead ii chloride, lead chloride, plumbous chloride, lead 2+ chloride, lead chloride pbcl2, pbcl2, ccris 7565, lead ii chloride, ultra dry
PubChem CID 24459
SMILES [Cl-].[Cl-].[Pb++]
Visualizza altre specifiche

Prodotti 3
Codice del prodotto Marca Quantità Prezzo Quantità e disponibilità  
Codice del prodotto Marca Quantità Prezzo Quantità e disponibilità  
11340058
SDS Vedere i documenti
Thermo Scientific Alfa Aesar
042841.04
2 g
69.35€
2g
Effettua il per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso!
11320058
SDS Vedere i documenti
Thermo Scientific Alfa Aesar
042841.09
10 g
183.92€
10g
Effettua il per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso!
11330058
SDS Vedere i documenti
Thermo Scientific Alfa Aesar
042841.18
50 g
775.86€
50g
Effettua il per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso!
Descrizione

Descrizione

Lead chloride is used in the synthesis of lead titanate and barium lead titanate ceramics; employed in the production of infrared transmitting glass and ornamental glass (aurene glass); useful as an electrode in geophysical applications and in solar cells. Analytical reagent, preparation of lead salts, as solder and flux. Pattinson's white lead, pigment in white paint, is the basic lead chloride.

This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.

Specifica

Identificatori chimici

7758-95-4
278.10
HWSZZLVAJGOAAY-UHFFFAOYSA-L
24459
Cl2Pb
MFCD00011157
lead dichloride, lead ii chloride, lead chloride, plumbous chloride, lead 2+ chloride, lead chloride pbcl2, pbcl2, ccris 7565, lead ii chloride, ultra dry
[Cl-].[Cl-].[Pb++]

Specifica

951°C
501°C
White
99.999% (Metal basis)
MFCD00011157
Soluble in hot water,alkali hydroxides and ammonium chloride solution. Insoluble in cold water and alcohol.
[Cl-].[Cl-].[Pb++]
278.10
278.1
White powder
Lead(II) chloride, ultra dry
7758-95-4
Powder
Cl2Pb
lead dichloride, lead ii chloride, lead chloride, plumbous chloride, lead 2+ chloride, lead chloride pbcl2, pbcl2, ccris 7565, lead ii chloride, ultra dry
HWSZZLVAJGOAAY-UHFFFAOYSA-L
λ²-lead(2+) dichloride
24459
Odorless
5.85 g/cm3 at 20°C
Videos
Sicurezza e movimentazione

Sicurezza e movimentazione

P201-P202-P260-P264b-P270-P271-P281-P301+P312-P304+P340-P308+P313-P330-P501c

H302+H332-H350-H360Df-H372

missing translation for 'dotInformation' : DOT Class: 6.1, Packaging Group: III

missing translation for 'einecsNumber' : 231-845-5

missing translation for 'tsca' : Yes

Recommended Storage : Ambient temperatures

Identificativo prodotto
  • Lead(II) chloride, ultra dry

Avvertenza
  • Pericolo

Categoria di pericolo
  • Tossicità acuta Categoria 4
  • Tossicità per la riproduzione Categoria 1A
  • Tossicità specifica per organi bersaglio (esposizione ripetuta) Categoria 2
  • PERICOLO ACUTO PER L'AMBIENTE ACQUATICO Acuto 1
  • PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 1

Indicazioni di pericolo
  • H302-Nocivo se ingerito.
  • H332-Nocivo se inalato.
  • H360Df-Può nuocere al feto. Sospettato di nuocere alla fertilità.
  • H373-Può provocare danni agli organi.
  • H410-Molto tossico per gli organismi acquatici con effetti di lunga durata.

Consigli di prudenza
  • P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
  • P201-Procurarsi istruzioni specifiche prima dell'uso.
  • P273-Non disperdere nell'ambiente.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P405-Conservare sotto chiave.
  • P501-Smaltire il prodotto/recipiente in .

SDS
Documenti

Documenti

Product Certifications

RUO – Research Use Only

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato