Macherey-Nagel™ HYDRODEX™ β-PM Capillary Columns for GC

Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ HYDRODEX™ β-PM Capillary Columns for GC are phases with 7 β-cyclodextrin glucose units for enantiomer separation in gas chromatography. This hydrophilic phase with short polar ligants is a chemically non-bonded phase.

1310.00€ - 1965.00€

Specifica

Diametro (sistema metrico) 0.4 mm
Diametro (sistema metrico) interno 0.25 mm
Stationary Phase Hydrodex β-PM
Tipo GC Capillary Column
Temperatura max For isothermal operations: 230°C, For short isotherms in a temperature program: 250°C
Visualizza altre specifiche

Allerta:

Water as solvent is strictly forbidden for all cyclodextrin phases. It is recommended to dry the sample and dissolve it in an appropriate nonpolar solvent.


Prodotti 2
Codice del prodotto Marca Lunghezza (sistema metrico) Prezzo Quantità e disponibilità  
Codice del prodotto Marca Lunghezza (sistema metrico) Prezzo Quantità e disponibilità  
10524922
Vedere i documenti
Macherey-Nagel™
723370.25
25 m
1310.00€
Pezzo
Solo null disponibili
In stock
Aggiungi al carrello
 
10748812
Vedere i documenti
Macherey-Nagel™
723370.50
50 m
1965.00€
Pezzo
Solo null disponibili
Spedizione stimata: 01-08-2025
Aggiungi al carrello
 
Descrizione

Descrizione

A major advantage of HYDRODEX columns are that many compounds can be analyzed without derivatization. However, for certain substances, enantioselectivity can be favorably influenced by formation of derivatives. Regioselective derivatization of the hydroxyl groups leads to phases with varying enantioselectivity, which are well suited for GC enantiomer analyses.

It is not possible to make a general prediction about whichHYDRODEX™ phase could solve a given separation task. Even for compounds with small structural differences or within homologous series, the enantiodifferentiation can be quite different.

  • Base material: cyclic oligosaccharides consisting of seven β-cyclodextrin glucose units bonded through α-1,4-linkages
  • heptakis-(2,3,6-tri-O-methyl)-β-cyclodextrin
  • Ligands: R2=R3=R6=methyl; n=2
  • Due to the high melting point of the phases, they are diluted with optimized polysiloxanes
  • Recommended for hydroxycarboxylic acid esters, alcohols, diols, olefins, lactones, acetals
Specifica

Specifica

0.4 mm
Hydrodex β-PM
For isothermal operations: 230°C, For short isotherms in a temperature program: 250°C
Hydrodex β-PM
1 Each
0.25 mm
GC Capillary Column
Enantiomer Separation
Polar
Videos
SDS
Documenti

Documenti

Product Certifications
Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato