missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns
Designed for method optimization and parameter screening for capture of monoclonal antibodies. Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns come ready-to-use for convenience.
Marca: Cytiva 28-9269-76
Questo articolo non è restituibile.
Consulta la politica di reso
Descrizione
- Ready-to-use columns for convenient process development
- Rigid, highly cross-linked agarose matrix
- Bed height of 10cm is designed to allow method optimization and parameter screening
- Easily connected in series to achieve 20cm bed height
- Small bed volume (4.7mL) gives fast result and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity
MabSelect
- For capture of MAbs from large sample volumes
- Prepacked with protein A-derived media
- Compatible with high flow rates and high pressure when scaling up
- Increased binding capacity enables purification of MAbs from high-level expression feedstock
- Also optimized for Fc-fusion proteins
- Very low, unspecific binding due to high ligand selectivity and matrix hydrophilicity
- Prepacked with protein A-derived media
- With novel, alkali-tolerant recombinant protein A ligand that provides greater stability and allows use of 0.1 to 0.5M sodium hydroxide for cleaning-in-place (CIP)
- Enhanced protease resistance resulting in lower ligand leakage
- High dynamic binding capacity

Specifica
8M Urea, 6M Guanidine Hydrochloride, 2% Benzyl Alcohol or 20% Ethanol | |
Stoppers at the inlet and outlet | |
Filter | |
≈40mg Human IgG | |
HiScreen MabSelect Xtra Prepacked Column | |
10cm | |
Recombinant Protein A (E.coli) | |
Polypropylene | |
3bar | |
2° to 8°C |
HiScreen MabSelect Xtra Prepacked Column | |
1 x 4.7mL | |
0.3 in. | |
0.77cm | |
3.93 in. | |
Designed for method optimization and parameter screening for capture of monoclonal antibodies | |
Epoxy Activation | |
75μm | |
3 to 10 | |
Column |
Sicurezza e movimentazione
Identificativo prodotto
Avvertenza
Categoria di pericolo
Indicazioni di pericolo
Consigli di prudenza
Informazioni supplementari
- HiScreen MabSelect Xtra
Avvertenza
- Attenzione
Categoria di pericolo
- Liquido infiammabile Categoria 3
Indicazioni di pericolo
- H226-Liquido e vapori infiammabili.
Consigli di prudenza
- P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
Informazioni supplementari
- MIXTURE LIST-Contiene: ethanol
Correzione del contenuto del prodotto
Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.
Titolo del prodotto
Individuate un'opportunità di miglioramento?Condividi una correzione di contenuto