missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ PureLink™ RNA Mini Kit

The PureLink RNA Mini Kit is a column-based kit used to isolate high-quality total RNA from a wide variety of sample types in 20 minutes using standard laboratory equipment.


Descrizione

Descrizione

The PureLink RNA Mini Kit is a column-based kit used to isolate high-quality total RNA from a wide variety of sample types in 20 minutes using standard laboratory equipment. The kit includes RNase-free lysis and wash solutions that protect RNA from RNases while liberating the RNA from DNA, proteins, and other cellular debris. The fast spin-column workflow is ideal for processing low to mid-throughput batch sizes. The advanced PureLink RNA Mini spin column design allows for maximum sample input (200 mg of tissue) and RNA recovery (up to 1000 μg). This means that users can process both small and large sample sizes with the same RNA isolation kit.

  • Process sample inputs from 5–200 mg of animal/plant tissue or from 0.5 x 106 to 108 tissue culture cells with one spin column in 20 minutes
  • Isolate more RNA than competitor mini spin columns: up to 1000 μg of total RNA from one column
  • Use isolated RNA in most applications without the need for further DNase treatment (very low minimal residual DNA carry over)
  • Flexible–optional on-column or post-isolation DNase treatment is available with PureLink DNase Set (Cat. No. 12185010) for easy removal of residual DNA

Extra-large binding capacity enables rapid RNA purification using standard laboratory equipment

The PureLink RNA Mini Kit provides rapid purification of total RNA from a wide range of cells and tissue types to yield up to 1000 μg of purified RNA from a single extraction (see Figure 1). High-quality total RNA can be obtained from mini- to midi-prep amounts of starting material with just trace amounts of residual genomic DNA contamination. The extra-large binding capacity enables one kit to handle most RNA isolation needs in a quick 20 minute protocol without the need for special sample processing instruments.

Easy, optional, on-column DNase treatment for sensitive applications

The PureLink RNA Mini Kit columns are highly efficient for isolating high quality total RNA while removing the majority of genomic DNA. In general, most applications requiring RNA from animal tissue or mammalian cell lines do not require additional DNase treatment. However, some applications such as gene expression analysis by qRT-PCR without intron-spanning primers or working with samples from organisms with very small or no introns may require more complete removal of residual contaminating DNA. The PureLink DNase Set (12185010) allows for convenient on-column digestion of DNA during the RNA isolation protocol. Treating with DNase while 'on-column' is easier and allows higher RNA recovery than treating with DNase after the RNA has been isolated. The PureLink DNase Set can also be used to remove residual DNA from RNA that has been previously purified. Both the 'on-column' and post-RNA purification workflows are options available with the PureLink DNase Set.

Simplified RNA purification

The PureLink RNA Mini Kit utilizes guanidine-isothiocyanate lysis buffer to protect the RNA during the isolation steps. Special RNase-free reagents combined with certified RNase-free silica membranes in a unique column configuration allow for a safe and easy procedure that can typically be completed in less than 20 minutes without the need of hazardous phenol/chloroform extraction, CsCl centrifugation, or LiCl or alcohol precipitation.

The PureLink RNA Mini Kit is recommended for use with the Homogenizer (Cat. No. 12183026), designed to homogenize cell or tissue lysates via centrifugation, prior to nucleic acid purification. The Homogenizer is especially effective for clarifying particulates from plant tissues.

Videos
Sicurezza e movimentazione

Sicurezza e movimentazione

Identificativo prodotto
  • PureLink RNA Mini Kit

Avvertenza
  • Pericolo

Categoria di pericolo
  • Tossicità acuta Categoria 4
  • PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 3
  • Lesione oculare grave/irritazione oculare Categoria 1
  • Lesione oculare grave/irritazione oculare Categoria 2
  • Corrosione/irritazione della pelle Categoria 1C
  • Corrosione/irritazione della pelle Categoria 2

Indicazioni di pericolo
  • H302-Nocivo se ingerito.
  • H314-Provoca gravi ustioni cutanee e gravi lesioni oculari.
  • H315-Provoca irritazione cutanea.
  • H319-Provoca grave irritazione oculare.
  • H412-Nocivo per gli organismi acquatici con effetti di lunga durata.

Consigli di prudenza
  • P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
  • P264-Lavare accuratamente dopo l'uso.
  • P270-Non mangiare, né bere, né fumare durante l'uso.
  • P273-Non disperdere nell'ambiente.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico/
  • P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
  • P303+P361+P353-IN CASO DI CONTATTO CON LA PELLE (o con i capelli): togliere immediatamente tutti gli indumenti contaminati. Sciacquare la pelle/fare una doccia.
  • P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
  • P310-Contattare immediatamente un CENTRO ANTIVELENI/un medico .
  • P330-Sciacquare la bocca.
  • P332+P313-In caso di irritazione della pelle: consultare un medico.
  • P337+P313-Se l'irritazione degli occhi persiste, consultare un medico.
  • P362+P364-Togliere tutti gli indumenti contaminati e lavarli prima di indossarli nuovamente.
  • P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.

Informazioni supplementari
  • MIXTURE LIST-Contiene: Thiocyanic acid

SDS
Documenti

Documenti

Product Certifications

For Research Use Only. Not for use in diagnostic procedures.

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato